CVE-2026-97180: OS command injection flaw found in ASSA ABLOY Seawing SC-1000 WebConfig
Compiled by RedTeamDaily · AI-assisted summaries · Human review not recorded for this version
Published · Updated
What happened
CERT Polska has reported an OS command injection vulnerability, CVE-2026-97180, in the WebConfig component of the ASSA ABLOY Seawing SC-1000. The article gives no affected versions, severity score or fix.
For IT people · Written by AI from 1 source · Report an error
- CERT Polska has reported an OS command injection vulnerability in ASSA ABLOY Seawing SC-1000 WebConfig.
- The vulnerability is tracked as CVE-2026-97180.
- OS command injection can allow an attacker to run commands on the underlying system.
- The article does not state affected versions, a severity score or a patch.
CERT Polska, the Polish national computer emergency response team, has published a notice about a vulnerability in WebConfig, a component of the ASSA ABLOY Seawing SC-1000. The flaw is classed as OS command injection and is tracked as CVE-2026-97180.
Command injection flaws occur when user-supplied input is passed to the operating system without proper checks, so an attacker may be able to run commands of their choosing. The source does not say how the flaw is triggered, whether it is exploited in the wild, or whether authentication is needed.
The article does not give affected firmware or software versions, a CVSS score, a patch date or a workaround. Readers should check the vendor's advisory and any CERT Polska follow-up for these details.
- What is affected?
- The WebConfig component of the ASSA ABLOY Seawing SC-1000 is affected by an OS command injection vulnerability.
- Who reported it?
- CERT Polska reported the vulnerability, according to the source article.
- Is a fix available?
- The article does not say whether a fix or workaround exists.
cve-2026-97180assa abloyseawing sc-1000webconfigos command injectioncert polskavulnerability
- Story priority
- Critical
- Highest CVSS
- 9.4
- Exploitation
- Not established here
- Sources
- 1
Why these vulnerabilities are attached
- CVE-2026-97180 · primary subject
Imported association; relationship review not recorded
Relationship review not recorded.
Affected products and technical context
These linked CVE records are maintained separately from the source summary above. They may supply affected versions or fixes that the original report did not include. Confirm the correct release branch with the vendor.
CVE-2026-97180 · CVSS 9.4
ASSA ABLOY Seawing SC-1000 WebConfig is vulnerable to remote command injection via HTTP request. Due to the lack of input sanitization, a privileged attacker can inject shell metacharacters in the server parameter, resulting in arbitrary command execution as the root user on the operating system.
Exploitation: Not established by our CVE data. This does not establish that attacks have not occurred.
Affected products: Not yet available in our structured data. Check affected version ranges.
Fixed releases: Not yet available in our structured data; consult the vendor advisory.
Choose the fix for your release branch. CVE record · NVD record
Sources and editorial review
Priority basis: Automatic priority from linked CVSS scores and CISA KEV status.
No named human review has been recorded for this story. See the source evidence below.
- Vulnerability in ASSA ABLOY Seawing SC-1000 WebConfig — CERT Polska (government source)
How severity and exploitation labels work · All source reports · Report an error
What to do
- Check whether you run the ASSA ABLOY Seawing SC-1000 and its WebConfig component.
- Look for a fix or mitigation from ASSA ABLOY, as the article does not list one.
Written by AI from the sources, checked against them
Source timeline (UTC) · 2 updates
Explore this report
Check my watchlist Requires sign-in · matches your saved products without AI.
Ask AI about this story
Optional follow-up answers generated from our coverage. Check the linked sources before acting.
Ask your own questionWho and what is in it
Government agencies